Econolite ASC/3 Programming Manual: A Comprehensive Overview (12/22/2025)
This manual details the Econolite ASC/3 controller‚ offering comprehensive programming guidance‚ troubleshooting‚ and support resources‚ including intensive courses and quickstart guides for Cobalt.
The Econolite ASC/3 controller represents a cornerstone in modern traffic management systems‚ providing robust and reliable control for intersections of varying complexity. This controller is widely recognized for its advanced capabilities and adaptability‚ serving as the central processing unit for coordinating traffic signals. Understanding its programming is crucial for optimizing traffic flow and enhancing safety.
Econolite offers a warranty for its control equipment‚ ensuring quality and performance. Technical support is readily available via phone (800-225-6480×457 or 714-630-3700×457) and email (support@econolite.com). The ASC/3’s functionality is further enhanced by the Cobalt interface‚ offering both graphical touchscreen and classic text-based views.
This manual serves as a detailed guide to navigating the ASC/3’s programming interface‚ covering essential aspects from configuration settings and time base adjustments to phase definitions and detector programming. It’s designed for both novice and experienced technicians seeking to maximize the controller’s potential.
What is the Econolite ASC/3?
The Econolite ASC/3 is a sophisticated‚ microprocessor-based traffic controller designed for precise and adaptable management of intersection traffic. It functions as the ‘brain’ of a traffic signal system‚ processing data from detectors and executing pre-programmed timing plans to optimize traffic flow. It’s a widely deployed solution known for its reliability and extensive feature set.
The ASC/3’s architecture allows for complex coordination with adjacent controllers‚ enabling synchronized traffic movement across multiple intersections. Its programming interface‚ accessible through the Cobalt controller‚ provides comprehensive control over all aspects of signal operation. The Cobalt interface offers both a user-friendly touchscreen and a traditional text-based view‚ mirroring the ASC/3’s core functionality.
Econolite provides dedicated support for the ASC/3‚ including intensive training courses covering configuration‚ controller settings‚ and time base adjustments. The ASC/3 Cobalt Quickstart Guide assists users in quickly becoming familiar with basic operations.
Key Features and Capabilities
The Econolite ASC/3 boasts a robust suite of features‚ central to its effectiveness as a traffic management system. These include advanced phase and detector programming‚ allowing for customized responses to varying traffic conditions. It supports detailed failed detector handling‚ ensuring continued operation even with sensor malfunctions.
A key capability is its coordination potential with neighboring controllers‚ enabling regional traffic synchronization. The system’s programming allows for diverse traffic actuation schemes‚ adapting signal timing based on real-time demand. Special function programming extends its versatility for unique intersection requirements.
Furthermore‚ the ASC/3 provides comprehensive reporting and diagnostic tools‚ aiding in system maintenance and performance analysis. Econolite’s technical support‚ reachable at 800-225-6480×457‚ offers expert assistance. Warranties cover control equipment‚ ensuring long-term reliability and peace of mind.

Hardware Components and System Architecture
The Econolite ASC/3 system comprises a controller unit‚ Cobalt interface‚ detector input modules‚ and serial/Ethernet communication interfaces‚ forming a complete traffic control solution.
ASC/3 Controller Unit
The ASC/3 Controller Unit serves as the central processing hub for traffic signal operations‚ managing phase sequencing‚ detector inputs‚ and communication with external systems. It’s designed for robust performance and reliability in demanding environments. This unit houses the core programming logic and executes the control strategies defined by the user through the programming interface;
Warranted by Econolite Control Products‚ Inc.‚ the controller ensures freedom from defects under specified conditions post-shipment. The unit’s internal architecture supports a wide range of traffic control applications‚ from simple pre-timed operations to complex adaptive control schemes. It’s crucial for maintaining efficient traffic flow and enhancing safety at intersections. The ASC/3’s capabilities are further extended through integration with the Cobalt controller interface‚ offering both graphical and text-based operational views.
Technical support is readily available via phone (800-225-6480×457 or 714-630-3700×457) or email (support@econolite.com) for any operational concerns.
Cobalt Controller Interface
The Cobalt interface significantly enhances the user experience when interacting with the Econolite ASC/3 controller. It provides two distinct display modes: a vibrant‚ full-color touchscreen graphical display and a classic‚ text-based view reminiscent of the original ASC/3 controller’s interface. This dual-mode functionality caters to diverse user preferences and operational needs.
Designed as a quickstart resource‚ the ASC3 Cobalt Quickstart Guide facilitates rapid familiarization with the controller’s basic operations; The graphical interface simplifies navigation and configuration‚ while the text-based mode offers a familiar environment for experienced technicians. Cobalt allows for efficient monitoring of phase status – whether a phase (1-16) or a failed detector is ON or OFF.
For detailed assistance‚ Econolite Technical Support remains accessible at 800-225-6480×457 / 714-630-3700×457 or support@econolite.com‚ ensuring seamless integration and operation.
Detector Input Modules
Detector input modules are critical components within the Econolite ASC/3 system‚ responsible for receiving and processing signals from field detectors. These modules translate detector state – whether a detector is currently active (ON) or inactive (OFF) – into data the controller can utilize for traffic signal timing adjustments.
Effective programming hinges on accurately defining detector states. The ASC/3 programming interface allows technicians to assign specific detectors to phases and configure their operational characteristics. Understanding failed detector handling is paramount; the system must reliably identify and respond to detector malfunctions to maintain safe and efficient traffic flow.
Monitoring detector status is simplified through the Cobalt interface‚ displaying whether any selected phase or failed detector is currently ON or OFF. Proper configuration and troubleshooting of detector inputs are essential for optimal controller performance. Contact Econolite Technical Support at 800-225-6480×457 for assistance.
Communication Interfaces (Serial‚ Ethernet)
The Econolite ASC/3 controller utilizes both serial and Ethernet communication interfaces‚ enabling connectivity for programming‚ monitoring‚ and coordination with other traffic management systems. Serial communication provides a traditional method for local access and configuration‚ while Ethernet facilitates remote control and data exchange.
These interfaces are crucial for downloading programming updates‚ retrieving diagnostic information‚ and integrating the ASC/3 into a wider network. Coordination with adjacent controllers relies heavily on reliable communication links‚ ensuring synchronized signal timing across intersections. The Cobalt controller’s interface enhances accessibility.

Troubleshooting communication issues often involves verifying cable connections‚ IP address settings‚ and network configurations. Econolite Technical Support (800-225-6480×457) can provide guidance on resolving connectivity problems. Proper interface setup is vital for efficient system operation and remote management capabilities.

Software and Programming Fundamentals
This section covers accessing the ASC/3 programming interface‚ navigating the main menu‚ configuring essential settings‚ and establishing a precise time base for optimal controller function.
Accessing the ASC/3 Programming Interface
The Econolite ASC/3 controller utilizes both a full-colour touchscreen graphical display‚ as found in the Cobalt unit‚ and a classic text-based interface reminiscent of earlier ASC/3 models. Accessing the programming interface typically involves establishing a connection via serial or Ethernet communication.
For Cobalt controllers‚ the touchscreen provides direct access to programming functions. Users navigate through menus and options using touch input. The text-based interface‚ accessible through a terminal emulator‚ requires specific communication settings – baud rate‚ parity‚ and data bits – to be correctly configured.
Successful connection is indicated by a login prompt. Valid credentials‚ specific to the agency or installation‚ are required to proceed. Once authenticated‚ the main menu appears‚ offering a range of programming options. Ensure proper security protocols are followed to prevent unauthorized access and modifications to critical traffic control parameters. Refer to Econolite Technical Support at 800-225-6480×457 for assistance with connection issues.
Main Menu Navigation
The ASC/3’s Main Menu serves as the central hub for all programming and configuration tasks. Accessible after successful login‚ it presents a hierarchical structure of options. Key functions include ‘Configuration‚’ ‘Controller‚’ and ‘Time Base‚’ covered extensively in the ASC/3 Intensive course.

Navigation is intuitive‚ utilizing either touchscreen selections on Cobalt units or text-based commands via a terminal. The ‘Configuration’ section allows for global settings adjustments. ‘Controller’ focuses on phase and detector programming‚ while ‘Time Base’ manages the system clock and synchronization.
Users can typically scroll through options using arrow keys or a scroll bar. Selecting an option drills down into a submenu with more specific settings. A ‘Back’ or ‘Return’ function allows navigating up the hierarchy. Careful attention to menu labels and prompts is crucial to avoid unintended changes. Econolite support (800-225-6480×457) can assist with menu navigation questions.
Configuration Settings
The Configuration section within the ASC/3 programming interface allows for system-wide adjustments impacting overall controller behavior. These settings define fundamental operational parameters‚ influencing how the controller responds to traffic demands and external inputs.
Key configurable elements include communication protocols (serial‚ Ethernet)‚ reporting parameters‚ and diagnostic settings; Users can define the controller’s identification‚ enabling clear distinction within a network. Furthermore‚ settings related to failed detector handling are crucial for maintaining traffic flow during malfunctions.
Careful consideration is vital when modifying these settings‚ as incorrect configurations can disrupt traffic patterns. Econolite recommends thorough testing after any changes. Referencing the ASC/3 Intensive course materials and Econolite Technical Support (800-225-6480×457) is advised for complex configurations. Warranty coverage applies to equipment free from user-induced configuration errors.
Time Base Configuration
The Time Base Configuration is fundamental to the ASC/3’s operation‚ establishing the core timing parameters for all phases and intervals. This section defines the controller’s internal clock and sets the foundation for precise traffic signal control. Accurate timekeeping is essential for coordinated systems and reliable operation.
Users can configure the date‚ time‚ and time zone‚ ensuring synchronization with external systems. Crucially‚ the time base dictates the duration of minimum green‚ yellow‚ and all-red intervals. Adjustments here directly impact pedestrian safety and vehicle progression.
Econolite recommends verifying the time base regularly‚ especially after power outages or system updates. Incorrect time settings can lead to unpredictable signal timing. For assistance‚ consult the ASC/3 Intensive course materials or contact Econolite Technical Support at 800-225-6480×457. Proper configuration is vital for maintaining warranty validity.

Phase and Detector Programming
This section covers defining phases‚ assigning detectors‚ handling failed detector states‚ and establishing precise phase sequencing and timing for optimal traffic flow control.
Phase Definitions and Assignments
Phase definitions within the Econolite ASC/3 controller are fundamental to traffic signal operation‚ representing distinct combinations of green time for specific movements. Each phase‚ numbered 1 through 16‚ requires careful assignment based on intersection geometry and traffic demands. Proper phase assignment ensures efficient and safe traffic progression.
The programming interface allows for detailed configuration of each phase‚ including the associated movements (protected‚ permitted‚ or exclusive). Assigning detectors to phases is crucial for actuation‚ enabling the controller to respond dynamically to traffic presence. Understanding the interplay between phases and detectors is key to optimizing signal timing.
Incorrect phase definitions or assignments can lead to conflicts‚ delays‚ and increased risk of accidents. Therefore‚ thorough planning and verification are essential. The ASC/3 allows for flexible phase sequencing‚ accommodating complex intersection layouts and traffic patterns. Careful consideration must be given to pedestrian phases and coordination with adjacent signals.
Detector Programming (ON/OFF States)
Detector programming within the Econolite ASC/3 centers on defining the ‘ON’ and ‘OFF’ states‚ dictating how the controller interprets signals from field detectors. An ‘ON’ state signifies vehicle presence‚ triggering phase extensions or recalls‚ while ‘OFF’ indicates no detection. Precise configuration of these states is vital for accurate traffic actuation.
The ASC/3 allows programmers to customize detector parameters‚ including sensitivity‚ call extension timers‚ and minimum green times. Properly setting these parameters prevents false calls and ensures responsive signal timing. Understanding detector types – inductive loops‚ video detection‚ and radar – is crucial for optimal programming. The selected active phase or any phase failed detector is ON or OFF.
Incorrect detector programming can lead to inefficient signal operation‚ unnecessary delays‚ and even safety hazards. Thorough testing and calibration are essential to verify detector functionality and ensure reliable performance. Econolite Technical Support (800-225-6480×457) can provide assistance with complex detector configurations.
Failed Detector Handling
Robust failed detector handling is critical for maintaining safe and efficient traffic flow when a detector malfunctions within the Econolite ASC/3 system. The controller offers several strategies to mitigate the impact of detector failures‚ including fallback modes and alternative phasing schemes.
Programmers can configure the ASC/3 to automatically switch to pre-defined plans upon detecting a detector failure; These plans might involve fixed timing or actuation based on remaining functional detectors. The system can also log failed detector events for diagnostic purposes‚ aiding in swift repairs. The selected active phase or any phase failed detector is ON or OFF.
Proper configuration prevents signal lockup and ensures continued operation‚ albeit potentially with reduced efficiency. Econolite recommends regular detector testing and preventative maintenance to minimize failures. For assistance with configuring failed detector handling‚ contact Econolite Technical Support at 800-225-6480×457.
Phase Sequencing and Timing
Precise phase sequencing and timing are fundamental to effective traffic control within the Econolite ASC/3 system. Programmers define the order in which phases operate‚ ensuring smooth transitions and minimizing conflicts. The ASC/3 allows for flexible sequencing‚ accommodating complex intersection layouts and traffic patterns.
Timing parameters‚ including minimum green times‚ yellow change intervals‚ and red clearance intervals‚ are meticulously configured to prioritize safety and optimize throughput. The controller supports both pre-timed and actuated operation‚ adapting to real-time traffic demands. Careful consideration must be given to pedestrian crossing times and coordination with adjacent signals.
Advanced features enable split phasing‚ overlap phasing‚ and dual-ring operation‚ enhancing capacity and reducing delays. Thorough testing and observation are crucial to validate timing plans and ensure optimal performance. Econolite’s support team (800-225-6480×457) can assist with complex sequencing scenarios.

Advanced Programming Concepts
Explore coordination with adjacent controllers‚ traffic actuation schemes‚ special function programming‚ and robust reporting/diagnostic tools within the Econolite ASC/3 system.
Coordination with Adjacent Controllers
Effective traffic management often necessitates seamless coordination between neighboring intersections. The Econolite ASC/3 facilitates this through advanced communication protocols‚ enabling controllers to share real-time data regarding traffic flow and signal timing. This inter-controller communication minimizes delays and optimizes overall network efficiency. Programming involves establishing communication links – typically serial or Ethernet – and defining data exchange parameters.
Key considerations include defining lead/lag relationships‚ coordinating phase sequences to create progressive movement‚ and implementing strategies for handling conflicting demands. The system allows for customizable coordination plans‚ adapting to varying traffic patterns throughout the day. Proper configuration ensures smooth transitions between intersections‚ reducing stops and improving travel times. Econolite Technical Support (800-225-6480×457) can provide detailed guidance on complex coordination scenarios‚ ensuring optimal performance and network-wide synchronization.
Traffic Actuation Schemes
The Econolite ASC/3 supports a variety of traffic actuation schemes‚ allowing for dynamic signal timing adjustments based on real-time demand. These schemes range from simple fixed-time operation to fully-actuated control‚ where phases are extended or terminated based on detector inputs. Programming involves defining detector configurations – ON/OFF states – and associating them with specific phases.
Common schemes include semi-actuated operation (main street green extended by side street calls) and fully-actuated operation (all phases respond to detector inputs). The system also supports advanced features like gap-out‚ max-out‚ and force-off‚ providing granular control over phase timing. Careful consideration must be given to detector placement and sensitivity to ensure accurate traffic detection. For detailed assistance‚ contact Econolite Technical Support at 800-225-6480×457. Proper implementation of actuation schemes optimizes traffic flow and minimizes unnecessary delays.
Special Function Programming
The Econolite ASC/3 offers specialized functions beyond standard phase and detector programming‚ enhancing its adaptability. These include features for pedestrian control‚ railroad preemption‚ and emergency vehicle priority. Programming these functions requires accessing specific menus within the ASC/3 interface‚ often involving configuration settings and timing parameters.
For example‚ pedestrian push buttons can be programmed to extend crossing times‚ while railroad preemption allows for immediate signal clearing upon detection of an approaching train. Emergency vehicle preemption utilizes specialized equipment to request a green light. Detailed documentation and the ASC/3 Intensive course cover these advanced capabilities. Remember to consult Econolite Technical Support (800-225-6480×457) for complex implementations. Proper configuration ensures these functions operate reliably and safely‚ improving overall traffic management.
Reporting and Diagnostics
The Econolite ASC/3 controller provides robust reporting and diagnostic capabilities crucial for maintaining optimal performance. The system logs various events‚ including detector activations‚ phase changes‚ and error conditions. Accessing these logs through the programming interface allows technicians to analyze traffic patterns and identify potential issues.
Common error codes are documented within the manual and can indicate problems with detector loops‚ communication interfaces‚ or internal controller functions. Utilizing these diagnostics‚ alongside Econolite Technical Support (800-225-6480×457)‚ facilitates efficient troubleshooting. The Cobalt controller’s display‚ in both graphical and text modes‚ aids in visualizing system status. Regular review of reports and diagnostic data is essential for proactive maintenance and ensuring the longevity of the traffic control system.

Troubleshooting and Support
Effective troubleshooting relies on understanding error codes and utilizing Econolite’s technical support resources (800-225-6480×457). Intensive courses and guides are available.
Common Error Codes
Error codes within the Econolite ASC/3 system provide crucial diagnostic information for identifying and resolving controller malfunctions. While a complete listing is extensive‚ several frequently encountered codes warrant specific attention. A “Phase Failed” error‚ often indicated by a detector being constantly ON or OFF‚ requires immediate investigation of detector wiring and functionality. Communication errors‚ impacting coordination with adjacent controllers‚ may stem from serial or Ethernet interface issues.

Time Base discrepancies can trigger errors related to cycle length or offset settings. Regularly reviewing configuration settings is vital. Further‚ memory-related errors might necessitate a controller reset or software update. Econolite’s technical support documentation provides detailed explanations of each error code‚ alongside recommended corrective actions. Remember to document all error occurrences and the steps taken to resolve them‚ aiding in future troubleshooting efforts and potentially identifying recurring system weaknesses. Proper error code interpretation is fundamental to maintaining optimal traffic flow and system reliability.
Econolite Technical Support Contact Information
For dedicated assistance with your Econolite ASC/3 controller‚ several support channels are readily available. Direct phone support can be reached at 800-225-6480 extension 457‚ or internationally at 714-630-3700 extension 457. These lines are staffed by experienced technicians capable of addressing a wide range of programming and operational inquiries;
Email support is also accessible via support@econolite.com‚ allowing for detailed issue descriptions and file attachments. Econolite’s website hosts a comprehensive knowledge base‚ featuring FAQs‚ troubleshooting guides‚ and software updates. Furthermore‚ consider leveraging the extensive resources available through authorized Econolite training partners. When contacting support‚ be prepared to provide your controller’s serial number‚ software version‚ and a clear description of the problem encountered. Prompt and accurate information expedites the resolution process‚ minimizing traffic disruption and ensuring system efficiency.
ASC/3 Intensive Course Details
The ASC/3 Intensive course is a hands-on‚ in-depth training program designed to equip professionals with advanced proficiency in Econolite ASC/3 controller programming and operation. This comprehensive course covers all functions accessible from the Main Menu‚ including detailed exploration of Configuration settings‚ Controller parameters‚ and Time Base adjustments.
Participants will gain practical experience in phase and detector programming‚ failed detector handling‚ and advanced phase sequencing techniques. The curriculum also delves into coordination strategies for adjacent controllers‚ traffic actuation schemes‚ and specialized function programming. Emphasis is placed on utilizing reporting and diagnostic tools for effective system monitoring and troubleshooting. This intensive format ensures participants leave with the skills necessary to confidently manage and optimize complex traffic control systems. Prior experience with traffic signal controllers is recommended‚ but not required‚ for successful course completion.
Cobalt Quickstart Guide Resources
The ASC3 Cobalt Quickstart Guide serves as an introductory resource for individuals new to the Cobalt controller‚ designed to facilitate rapid familiarization with its basic operational principles. This guide bridges the gap between traditional ASC/3 programming and the Cobalt’s modern interface‚ highlighting key differences and similarities.
Users will learn to navigate the Cobalt’s dual display modes – the full-color touchscreen and the classic text-based view – enabling a comfortable transition for those accustomed to the Econolite ASC/3 controller. The guide provides step-by-step instructions for essential tasks‚ such as accessing core functions and interpreting system status. It’s a valuable tool for quickly understanding the Cobalt’s capabilities and initiating effective traffic management. Further detailed information and support are readily available through Econolite Technical Support at 800-225-6480×457.